DR. BYRON JUDSON COLLEY III M.D.
NPI 1679665640
Internal Medicine - Clinical Cardiac Electrophysiology in Birmingham, AL


Quality Rating: 78.57 out of 100 score

NPI Status: Active since September 28, 2006

Contact Information

3686 GRANDVIEW PKWY STE 720
BIRMINGHAM, AL
ZIP 35243
Phone: (205) 971-7500
Fax: (205) 971-7572

Get Directions Reviews

  • Individual
  • Male
  • Years of Experience 26
  • Internal Medicine
  • Clinical Cardiac Electrophysiology
  • Accepts Insurance
  • Accepts Medicare Approved Payment
  • PECOS Enrolled

About BYRON COLLEY

This page provides the complete NPI Profile along with additional information for Byron Colley, an internist established in Birmingham, Alabama with a medical specialization in Internal Medicine, focusing in clinical cardiac electrophysiology and more than 26 years of experience. The healthcare provider is registered in the NPI registry with number 1679665640 assigned on September 2006. The practitioner's primary taxonomy code is 207RC0001X with license number 24202 (AL). The provider is registered as an individual and his NPI record was last updated 3 years ago.

NPI
1679665640
Provider Name
DR. BYRON JUDSON COLLEY III M.D.
Gender
Male
Entity Type
Individual
Location Address
3686 GRANDVIEW PKWY STE 720 BIRMINGHAM, AL 35243
Location Phone
(205) 971-7500
Location Fax
(205) 971-7572
Mailing Address
3686 GRANDVIEW PKWY STE 720 BIRMINGHAM, AL 35243
Mailing Phone
(205) 971-7538
Mailing Fax
(205) 971-7572
Medical School Name
OTHER
Graduation Year
2000
Is Sole Proprietor?
No
Enumeration Date
09-28-2006
Last Update Date
06-09-2022
Code Navigator

An internist like Byron Colley is a physician who has completed an internal medicine residency and is board-certified or board-eligible in an internist specialty. Internists are trained to care for adults of all ages for many different medical conditions. An internist typically monitors chronic physical conditions, identifies acute diseases, provides family planning, provides counseling about wellness and disease prevention, etc.

Location Map

Secondary Locations

  • 970 Lakeland Dr Suite 61
    Jackson, MS 39216
    (601) 982-7850
  • 1040 River Oaks Dr Ste 301
    Flowood, MS 39232
    (205) 971-7500

Specialty - Primary Taxonomy

The NPI enumerator requires providers to submit at least one taxonomy code. A taxonomy code is a unique 10-character code that describes the healthcare provider type, classification, and the area of specialization. There could be only one primary taxonomy code per NPI record. For individual NPIs the license data is associated to the taxonomy code.

Classification

Internal Medicine Clinical Cardiac Electrophysiology

Taxonomy Code
207RC0001X
Type
Allopathic & Osteopathic Physicians
License No.
24202
License State
AL
Taxonomy Description
A field of special interest within the subspecialty of cardiovascular disease, specialty of Internal Medicine, which involves intricate technical procedures to evaluate heart rhythms and determine appropriate treatment for them.

Secondary Taxonomies

The provider has reported to the NPI enumerator additional taxonomy codes. Multiple taxonomy codes may represent subspecialties or other areas of specialization the provider maybe licensed to practice.

No. Taxonomy Code Type Classification /
Specialization
License No. (State)
1207R00000XAllopathic & Osteopathic Physicians

Internal Medicine

23975 (SC)
2207RC0000XAllopathic & Osteopathic Physicians

Internal Medicine
Cardiovascular Disease

20613 (MS)
3207RC0000XAllopathic & Osteopathic Physicians

Internal Medicine
Cardiovascular Disease

ME 98666 (FL)
4207RC0001XAllopathic & Osteopathic Physicians

Internal Medicine
Clinical Cardiac Electrophysiology

20613 (MS)
5207RC0001XAllopathic & Osteopathic Physicians

Internal Medicine
Clinical Cardiac Electrophysiology

ME 98666 (FL)

Insurance Plans Accepted

According to publicly available information the provider might be accepting the following health plans from these health insurance companies:

  • Choice Bronze HSA (QualChoice) - POS
  • Complete Gold - PPO
  • Complete Gold + Vision + Adult Dental - PPO
  • Complete Silver (QualChoice) - POS
  • Connected Silver - PPO
  • Connected Silver (QualChoice) - POS
  • Connected Silver (QualChoiceLife) - PPO
  • Connected Silver + Vision + Adult Dental - PPO
  • Elite Bronze - PPO
  • Elite Bronze + Vision + Adult Dental - PPO
  • Elite Gold (QualChoice) - POS
  • Elite Gold (QualChoiceLife) - PPO
  • Everyday Bronze - PPO
  • Everyday Bronze + Vision + Adult Dental - PPO
  • Everyday Gold - PPO
  • Everyday Gold + Vision + Adult Dental - PPO
  • Everyday Silver (QualChoiceLife) - PPO
  • Focused Silver - PPO
  • Focused Silver + Vision + Adult Dental - PPO
  • Standard Expanded Bronze - PPO
  • Complete Gold - EPO
  • Complete Gold + Vision + Adult Dental - EPO
  • Elite Bronze - EPO
  • Elite Bronze + Vision + Adult Dental - EPO
  • Elite Gold - EPO
  • Elite Gold + Vision + Adult Dental - EPO
  • Elite Silver - EPO
  • Elite Silver + Vision + Adult Dental - EPO
  • Everyday Bronze - EPO
  • Everyday Bronze + Vision + Adult Dental - EPO
  • Focused Silver - EPO
  • Focused Silver + Vision + Adult Dental - EPO
  • Standard Expanded Bronze - EPO
  • Standard Expanded Bronze + Vision + Adult Dental - EPO
  • Standard Gold - EPO
  • Standard Gold + Vision + Adult Dental - EPO
  • Standard Silver - EPO
  • Choice Bronze HSA - HMO
  • Choice Bronze HSA + Vision + Adult Dental - HMO
  • Complete Gold - HMO
  • Complete Gold + Vision + Adult Dental - HMO
  • Complete Silver - HMO
  • Complete Silver + Vision + Adult Dental - HMO
  • Everyday Bronze - HMO
  • Everyday Bronze + Vision + Adult Dental - HMO
  • Everyday Gold - HMO
  • Everyday Gold + Vision + Adult Dental - HMO
  • Focused Silver - HMO
  • Focused Silver + Vision + Adult Dental - HMO
  • Standard Expanded Bronze - HMO
  • Standard Expanded Bronze + Vision + Adult Dental - HMO
  • Standard Gold - HMO
  • Standard Gold + Vision + Adult Dental - HMO
  • Standard Silver - HMO
  • Complete Gold - EPO
  • Complete Gold + Vision + Adult Dental - EPO
  • Elite Bronze - EPO
  • Elite Bronze + Vision + Adult Dental - EPO
  • Elite Gold - EPO
  • Elite Gold + Vision + Adult Dental - EPO
  • Elite Silver - EPO
  • Elite Silver + Vision + Adult Dental - EPO
  • Everyday Bronze - EPO
  • Everyday Bronze + Vision + Adult Dental - EPO
  • Focused Silver - EPO
  • Focused Silver + Vision + Adult Dental - EPO
  • Standard Expanded Bronze - EPO
  • Standard Expanded Bronze + Vision + Adult Dental - EPO
  • Standard Gold - EPO
  • Standard Gold + Vision + Adult Dental - EPO
  • Standard Silver - EPO
  • Clear Silver - EPO
  • Elite Bronze - EPO
  • Elite Bronze + Vision + Adult Dental - EPO
  • Elite Gold - EPO
  • Elite Gold + Vision + Adult Dental - EPO
  • Enhanced Diabetes Care Silver with $0 Drug Options - EPO
  • Enhanced Diabetes Care Silver with $0 Drug Options + Vision + Adult Dental - EPO
  • Everyday Bronze - EPO
  • Everyday Bronze + Vision + Adult Dental - EPO
  • Everyday Gold - EPO
  • Everyday Gold + Vision + Adult Dental - EPO
  • Focused Silver - EPO
  • Focused Silver + Vision + Adult Dental - EPO
  • Standard Expanded Bronze - EPO
  • Standard Expanded Bronze + Vision + Adult Dental - EPO
  • Standard Gold - EPO
  • Standard Gold + Vision + Adult Dental - EPO
  • Standard Silver - EPO
  • Standard Silver + Vision + Adult Dental - EPO
  • Blue HSA Bronze - PPO
  • Blue Protect - PPO
  • Blue Saver Bronze - PPO
  • Blue Saver Silver EPO - EPO
  • Blue Standardized Silver EPO - EPO
  • Blue Value Gold - PPO
  • Blue Value Silver - PPO
  • Blue Access Gold for Business - PPO
  • Blue Choice Platinum for Business - PPO
  • Blue HSA Silver for Business - PPO
  • Blue Saver Bronze for Business - PPO
  • Blue Saver Gold for Business - PPO
  • Blue Secure Gold for Business - PPO
  • Blue Secure Silver for Business - PPO
  • Connect Bronze 5500 Indiv Med Deductible Enhanced Diabetes Care - EPO
  • Connect Bronze 6500 Indiv Med Deductible - EPO
  • Connect Bronze 8500 Indiv Med Deductible - EPO
  • Connect Bronze CMS Standard - EPO
  • Connect Gold 2000 Indiv Med Deductible - EPO
  • Connect Gold CMS Standard - EPO
  • Connect Silver 3800 Indiv Med Deductible Enhanced Diabetes Care - EPO
  • Connect Silver 4000 Indiv Med Deductible - EPO
  • Connect Silver 6500 Indiv Med Deductible - EPO
  • Connect Silver CMS Standard - EPO
  • Bronze 4 - HMO
  • Bronze 8 - HMO
  • Gold 1 - HMO
  • Gold 1 with Adult Vision Services - HMO
  • Gold 8 - HMO
  • Silver 1 - HMO
  • Silver 1 with Adult Vision Services - HMO
  • Silver 12 with First 4 Primary Care Visits Free - HMO
  • Silver 8 - HMO
  • Essential Bronze 6500 - POS
  • Essential Gold 1500 - POS
  • Freedom Silver 4000 - POS
  • Savings Bronze 7700 - POS
  • Standard Bronze 7500 - POS
  • Standard Gold 1500 - POS
  • Standard Silver 5000 - POS
  • UHC Bronze Copay Focus $0 Indiv Med Ded ($0 Virtual Urgent Care, No Referrals) - EPO
  • UHC Bronze Copay Focus $0 Indiv Med Ded ($0 Virtual Urgent Care, No Referrals) - HMO
  • UHC Bronze Copay Focus+ $0 Indiv Med Ded ($0 Virtual Urgent Care, Dental + Vision, No Referrals) - HMO
  • UHC Bronze Standard (No Referrals) - EPO
  • UHC Bronze Standard (No Referrals) - HMO
  • UHC Bronze Value ($0 Virtual Urgent Care, $3 Tier 2 Rx, No Referrals) - HMO
  • UHC Bronze Value ($0 Virtual Urgent Care, $5 Tier 2 Rx, No Referrals) - EPO
  • UHC Bronze Value+ ($0 Virtual Urgent Care, $3 Tier 2 Rx, Dental + Vision, No Referrals) - HMO
  • UHC Bronze Value+ ($0 Virtual Urgent Care, $5 Tier 2 Rx, Dental + Vision, No Referrals) - EPO
  • UHC Gold Advantage ($0 Virtual Urgent Care, $3 Tier 2 Rx, No Referrals) - EPO
  • UHC Gold Advantage+ ($0 Virtual Urgent Care, $3 Tier 2 Rx, Dental + Vision, No Referrals) - EPO
  • UHC Gold Copay Focus $0 Indiv Med Ded ($0 Virtual Urgent Care, $1 Tier 2 Rx, No Referrals) - HMO
  • UHC Gold Copay Focus $0 Indiv Med Ded ($0 Virtual Urgent Care, $3 Tier 2 Rx, No Referrals) - EPO
  • UHC Gold Copay Focus+ $0 Indiv Med Ded ($0 Virtual Urgent Care, $1 Tier 2 Rx, Dental + Vision, No Referrals) - HMO
  • UHC Gold Standard (No Referrals) - EPO
  • UHC Gold Standard (No Referrals) - HMO
  • UHC Gold Value ($0 Virtual Urgent Care, $1 Tier 2 Rx, No Referrals) - HMO
  • UHC Gold Value+ ($0 Virtual Urgent Care, $1 Tier 2 Rx, Dental + Vision, No Referrals) - HMO
  • UHC Silver Advantage ($0 Virtual Urgent Care, $3 Tier 2 Rx, No Referrals) - HMO
  • UHC Silver Advantage+ ($0 Virtual Urgent Care, $3 Tier 2 Rx, Dental + Vision, No Referrals) - HMO

Specific plan information not avaialable, please contact the provider to verify if your insurance plan is accepted.

Specific plan information not avaialable, please contact the provider to verify if your insurance plan is accepted.

*Please verify directly with this provider to make sure your insurance plan is currently accepted.

Additional Identifiers

The NPI Enumerator encourages providers to submit additional identifiers with their NPI application although the submission of this information is optional. The additional identifier(s) section includes other numbers or codes currently or formerly used as an identifier for the provider by other public healthcare entities. The identifiers may include UPIN, NSC, OSCAR, DEA, Medicaid State or PIN identification numbers.

Identifier Type / Code Identifier State Identifier Issuer
H6647300281OTHER (01)SOLE PROPRIETOR ID
09872218MEDICAID (05)MS 

Medicare Participation & PECOS Enrollment Status

Byron Colley is registered with Medicare and accepts claims assignment, this means the provider accepts the approved amount for the cost of rendered services as full payment. Participating providers may not charge beneficiaries more than the approved amount for their services. Please keep in mind that beneficiaries still have to pay a coinsurance or copayment amount for a visit or service.

Byron Colley is enrolled in PECOS and is eligible to order or refer health care services for Medicare patients. The provider is eligible to order or refer: Part B Clinical Laboratory and Imaging, Durable Medical Equipment (DME), a Home Health Agency (HHA) and Power Mobility Devices.

What is PECOS?
PECOS is the online Medicare enrollment management system or Provider, Enrollment, Chain and Ownership System. The PECOS system is a database of providers who have registered with CMS as providers or suppliers. PECOS is the primary source of information about verified Medicare professionals. Providers that want to participate in this program need to enroll in PECOS with their NPI number to avoid denied claims.

  • Is the provider registered in PECOS? Yes

  • PECOS PAC ID: 2668407578

    What is the PECOS Associate Control ID?
    A PAC ID is a unique 10-digit number assigned to an individual or organization healthcare provider in PECOS. The PAC ID is used to link together all the provider information, like tax identification numbers and organizational names. A PAC ID can be connected to multiple Enrollment IDs if an individual or organization has enrolled in PECOS more than once.

  • PECOS Enrollment ID: I20090810000308

    What is the Provider Enrollment ID?
    The Enrollment ID is a unique alphanumeric 15-digit code assigned to each new provider's PECOS enrollment application. The Enrollment ID is used to link together all the provider enrollment information like enrollment type, state, provider specialty, and reassignment of benefits.

  • Accepts Medicare Assignment? Yes

    What does it mean "accepts medicare assignment"?
    When a provider accepts Medicare assignment, the provider agrees to be paid directly by Medicare and to accept the payment amount approved by Medicare. Additionally, the provider agrees to not bill patients for more than the Medicare deductible and coinsurance amounts.
    A provider who doesn't accept assignment may charge you up to 15% over the Medicare-approved amount. This is known as the limiting charge. You may have to pay this amount, or it may be covered by another insurer.

  • Eligible to Order or Refer Part B Clinical Laboratory and Imaging: Yes

  • Eligible to Order or Refer Durable Medical Equipment (DMEPOS): Yes

  • Eligible to Order or Refer a Home Health Agency (HHA): Yes

  • Eligible to Order or Refer Power Mobility Devices: Yes

Areas of Expertise

The following services and procedures, recently provided to Medicare patients, illustrate the range of care this provider offers. This list reflects the variety of services available to all patients visiting the practice and is based on 2022 Medicare dataset. In general, the more frequently a provider treats specific conditions or performs particular procedures, the more experienced they become in addressing similar patient needs. The provider has delivered many of the services listed below to Medicare patients. Please note that this list does not include services provided to patients who are not covered by Medicare.

Blood creatinine level

A blood creatinine level test measures the amount of creatinine in your blood. Creatinine is a waste product that your body produces when it uses energy. High levels may indicate that your kidneys aren't working properly. This test is often used to monitor kidney health.

This service was performed 45 times for 45 patients

Comprehensive electrophysiologic evaluation with catheter destruction of abnormality causing atrial fibrillation (uncoordinated contraction of upper chambers of heart) by pulmonary vein isolation

This is a procedure to treat atrial fibrillation, a condition causing irregular heartbeats. It involves a detailed heart evaluation using electrophysiology. A catheter is then used to destroy the problematic area causing the issue. Specifically, isolation of the pulmonary vein is done to regulate the heartbeat.

This service was performed 65 times for 60 patients

Comprehensive electrophysiologic evaluation with catheter destruction of abnormality of upper chamber of heart causing supraventricular tachycardia (rapid heart rate)

This procedure is a detailed study of your heart's electrical activity. A thin tube (catheter) is inserted into your heart to identify and eliminate the area causing a fast heart rate. This helps restore normal heart rhythm, specifically targeting the upper chamber of the heart.

This service was performed 19 times for 18 patients

Coronary angioplasty and stenting

Coronary angioplasty and stenting is a procedure to open narrowed or blocked heart arteries. A thin tube is inserted into a blood vessel, usually in the leg or arm, and guided to the heart. A small balloon at the end of the tube is inflated to widen the artery. A stent, a small wire mesh tube, may be placed in the artery to keep it open.

This service was performed for 1-10 patients

Ct scan of blood vessels of chest with contrast

A CT scan of the chest with contrast is a non-invasive imaging test. It uses X-rays and a special dye to get detailed images of your blood vessels in the chest. This helps in diagnosing conditions related to heart and lungs.

This service was performed 45 times for 45 patients

Electrocardiogram (ecg) up to 30 days continuous with review and report by health care professional

An Electrocardiogram (ECG) is a non-invasive test that records the electrical signals in your heart. For up to 30 days, a small device will continuously monitor your heart's activity. A healthcare professional will then review the data and provide a report on your heart's function.

This service was performed 20 times for 20 patients

Established patient office or other outpatient visit, 20-29 minutes

This is a routine visit for patients who have already been seen by the healthcare provider. During this approximately 20-29 minute appointment, your health status will be evaluated and any necessary treatments or tests will be discussed. It's a chance to address any health concerns you may have.

This service was performed 88 times for 85 patients

Established patient office or other outpatient visit, 30-39 minutes

This is a routine check-up for patients who have previously visited our clinic. It involves a comprehensive review of your health and any ongoing treatments. The consultation lasts between 30-39 minutes, allowing enough time to discuss any concerns.

This service was performed 267 times for 254 patients

Established patient office or other outpatient visit, 40-54 minutes

This service involves a follow-up appointment for existing patients, lasting between 40 to 54 minutes. During this time, your healthcare provider will assess your current health status, discuss any changes or concerns, review your treatment plan, and answer any questions you may have.

This service was performed 187 times for 174 patients

Evaluation of cardiac rhythm monitor system, remote up to 30 days

This procedure involves remotely monitoring your heart rhythm for up to 30 days. A small device will record your heart's activity, which can be accessed by your healthcare team. This aids in diagnosing any irregularities or issues with your heart function.

This service was performed 622 times for 139 patients

Evaluation of single, dual, multiple lead or leadless pacemaker system or implantable defibrillator system, remote up to 90 days

This procedure involves remotely monitoring your pacemaker or implantable defibrillator system. Over a 90-day period, we check the device's performance and your heart's activity. This helps ensure the device is functioning properly and providing the best possible support for your heart health.

This service was performed 948 times for 542 patients

Evaluation of single, dual, multiple lead or leadless pacemaker system, remote up to 90 days

This procedure evaluates your pacemaker system remotely for up to 90 days. It checks whether single, dual, multiple lead, or leadless pacemakers are working properly. It's a safe, convenient way to ensure your heart device is functioning optimally.

This service was performed 646 times for 357 patients

Evaluation of single, dual, or multiple lead implantable defibrillator system, remote up to 90 days

This procedure involves remotely monitoring your implantable defibrillator system, which can have single, dual, or multiple leads. Over a period of up to 90 days, the system's performance is evaluated to ensure it's working properly and providing the necessary heart rhythm support.

This service was performed 325 times for 186 patients

External shock to heart to regulate heart beat

This procedure, known as cardioversion, uses an external electrical shock to restore your heart's normal rhythm. It's typically performed when irregular heartbeats, or arrhythmias, are causing severe symptoms and aren't responding to medications.

This service was performed 34 times for 32 patients

Follow-up hospital inpatient care per day, typically 25 minutes

Follow-up hospital inpatient care involves daily check-ups while you're admitted in the hospital. Typically, a healthcare provider spends about 25 minutes each day reviewing your condition, adjusting treatment if needed, and answering any questions you might have.

This service was performed 28 times for 22 patients

Follow-up hospital inpatient care per day, typically 35 minutes

Follow-up hospital inpatient care per day typically involves a 35-minute check-up by your healthcare provider. This service includes monitoring your health progress, adjusting your treatment plan if needed, and answering any questions you may have about your condition or care.

This service was performed 50 times for 32 patients

Hospital discharge day management, more than 30 minutes

Hospital discharge day management over 30 minutes involves a detailed process to ensure a smooth transition from hospital to home. It includes final examinations, discussion of your hospital stay, post-discharge instructions, and coordinating follow-up care.

This service was performed 13 times for 13 patients

Initial hospital inpatient care per day, typically 70 minutes

Initial hospital inpatient care per day, typically 70 minutes, refers to the daily medical service provided to patients admitted to the hospital. This includes a comprehensive evaluation, diagnosis, treatment plan, and monitoring of your health condition. It ensures your well-being during your hospital stay.

This service was performed 41 times for 39 patients

Insertion of catheters and destruction of tissue to treat abnormal heart rhythm

This procedure involves placing small tubes (catheters) into your heart via a blood vessel. These catheters emit energy that corrects irregular heartbeats by eliminating the problematic heart tissue. It's a common, minimally invasive method to treat abnormal heart rhythms.

This service was performed 39 times for 34 patients

Insertion of heart rhythm monitor under skin

The insertion of a heart rhythm monitor under the skin is a procedure to track your heart's activity. A small device is placed under your skin, recording your heart's rhythms continuously. This helps identify irregular heartbeats or conditions, aiding in your treatment.

This service was performed 13 times for 13 patients

Insertion of needle into vein for collection of blood sample

This procedure involves inserting a small needle into a vein, typically in your arm, to collect a blood sample. It's a quick and simple process to help diagnose or monitor health conditions. You may feel a small prick, but discomfort is minimal.

This service was performed 47 times for 47 patients

Insertion of pacemaker and upper and lower heart chamber electrode

A pacemaker insertion is a procedure where a small device, called a pacemaker, is implanted under your skin. This device uses electrical pulses to prompt the heart to beat at a normal rate. Electrodes are placed in the upper and lower chambers of your heart to help regulate your heartbeat.

This service was performed 13 times for 13 patients

Interrogation device evaluation(s), (remote) up to 30 days; implantable cardiovascular physiologic monitor system, implantable loop recorder system, or subcutaneous cardiac rhythm monitor system, remote data acquisition(s), receipt of transmissions and tec

This procedure involves the remote monitoring of an implanted device in your heart for up to 30 days. The device collects data about your heart's function which is transmitted and analyzed. The goal is to track your heart's rhythm and identify any abnormalities.

This service was performed 619 times for 147 patients

Low osmolar contrast material, 300-399 mg/ml iodine concentration, per ml

Low osmolar contrast material with 300-399 mg/ml iodine concentration is a diagnostic tool used in imaging procedures. It helps to enhance the visibility of specific areas in the body, aiding in accurate diagnosis. It's safe and generally well-tolerated by patients.

This service was performed 5,160 times for 45 patients

Management using the results of remote vital sign monitoring per calendar month, first 20 minutes

This service involves reviewing and managing your health data, which is remotely monitored and collected. Your vital signs like heart rate and blood pressure are tracked regularly throughout the month. The first 20 minutes of this data analysis per month is included in this service.

This service was performed 29 times for 14 patients

New patient office or other outpatient visit, 45-59 minutes

This is a first-time office or outpatient visit lasting between 45-59 minutes. The healthcare provider evaluates your health, discusses your medical history, and may suggest further tests or treatments. It's an opportunity to ask questions and understand your health better.

This service was performed 18 times for 18 patients

New patient office or other outpatient visit, 60-74 minutes

This is a first-time patient visit where a healthcare professional spends 60-74 minutes with you. It involves a comprehensive evaluation, including your medical history and current health condition. They'll also advise on preventive health measures and formulate a treatment plan if needed.

This service was performed 94 times for 94 patients

Pacemaker insertion or repair

Pacemaker insertion or repair is a procedure to help regulate your heartbeat. A small device, called a pacemaker, is implanted under the skin near your heart. This device sends electrical signals to prompt your heart to beat at a normal rate. In a repair procedure, the pacemaker may be adjusted, replaced, or the wires connecting it to your heart may be fixed.

This service was performed for 33 patients

Programming of dual lead implantable defibrillator system

Programming of a dual lead implantable defibrillator system involves adjusting settings on a device implanted in your chest. This device monitors your heart rhythm and delivers electrical pulses to correct irregular heartbeats, helping maintain a healthy heart rhythm.

This service was performed 38 times for 34 patients

Programming of dual lead pacemaker system

Programming of a dual lead pacemaker system is a procedure to adjust your heart's pacemaker settings. This process involves a small device, called a programmer, that communicates with your pacemaker to ensure it's working optimally for your heart's needs.

This service was performed 140 times for 126 patients

Programming of heart rhythm stimulation after drug infusion

Programming of heart rhythm stimulation after drug infusion is a process to regulate your heartbeat. After a medication is administered into your body, a device is programmed to monitor and correct irregular heart rhythms, ensuring your heart functions optimally.

This service was performed 34 times for 34 patients

Programming of multiple lead implantable defibrillator system

Programming of a multiple lead implantable defibrillator system involves adjusting settings on your implanted device to help control irregular heart rhythms. The process is non-invasive and helps ensure optimal device performance for maintaining heart health.

This service was performed 41 times for 38 patients

Programming of multiple lead pacemaker system

Programming of a multiple lead pacemaker system involves adjusting settings on your pacemaker device to optimize its function. This device uses electrical impulses to regulate your heart's rhythm. The procedure ensures it's working effectively for your specific needs.

This service was performed 15 times for 13 patients

Remote monitoring of physiologic parameters, initial set-up and patient education on use of equipment

Remote monitoring of physiologic parameters involves using special equipment to track vital signs like heart rate and blood pressure from a distance. The initial set-up includes installing the device and teaching the patient how to use it correctly for accurate readings.

This service was performed 14 times for 14 patients

Repair of left upper heart chamber with implant with review by radiologist

This is a procedure to fix a problem in your left upper heart chamber. An implant is used to correct the issue. After the procedure, a radiologist, a doctor who specializes in medical imaging, reviews the images to ensure everything is in order.

This service was performed 22 times for 22 patients

Routine electrocardiogram (ecg) using at least 12 leads with interpretation and report

An electrocardiogram (ECG) is a non-invasive test that records your heart's electrical activity. Using 12 leads attached to your body, it captures data to help identify heart conditions. A doctor interprets the results and provides a report.

This service was performed 640 times for 528 patients

Routine electrocardiogram (ecg) using at least 12 leads with interpretation and report only

A routine electrocardiogram (ECG) with 12 leads is a simple, non-invasive test that records the electrical activity of your heart. It helps in identifying heart conditions by detecting irregularities in your heart rhythms. The results are interpreted and a report is provided.

This service was performed 398 times for 347 patients

Ultrasound of heart blood flow, valves and chambers

An ultrasound of your heart, also known as an echocardiogram, is a test that uses sound waves to create detailed images of your heart. It helps doctors check the health of your heart's chambers, valves, and blood flow.

This service was performed 24 times for 22 patients

Ultrasound of heart blood flow, valves and chambers, follow-up

This procedure, an echocardiogram, uses sound waves to create images of your heart. It aids in assessing your heart's blood flow, chambers, and valves. It's a follow-up procedure, ensuring that your heart is functioning properly post-treatment.

This service was performed 56 times for 54 patients

Ultrasound of heart with color-depicted blood flow, rate and valve function

An ultrasound of the heart, also known as an echocardiogram, uses sound waves to create pictures of your heart. It shows the structure, movement, and blood flow within your heart. This helps assess the heart's health and function, including the valves and rate.

This service was performed 27 times for 25 patients

Ultrasound of heart with color-depicted blood flow, rate, direction and valve function

This is a heart ultrasound, also known as an echocardiogram. It uses sound waves to create pictures of your heart, showing how blood flows through it. The color depicts the blood flow's speed and direction. It also checks the heart's valves to ensure they're working properly.

This service was performed 27 times for 27 patients

Ultrasound of heart with color-depicted blood flow, rate, direction and valve function

This is a heart ultrasound, also known as an echocardiogram. It uses sound waves to create pictures of your heart, showing how blood flows through it. The color depicts the blood flow's speed and direction. It also checks the heart's valves to ensure they're working properly.

This service was performed 53 times for 52 patients

Ultrasound of heart with probe in esophagus, with report

This procedure, called a transesophageal echocardiogram, uses a small probe passed into your esophagus to capture detailed images of your heart. The report provides information about your heart's structure and function.

This service was performed 26 times for 24 patients

Ultrasound of heart, follow-up

A follow-up ultrasound of the heart, also known as an echocardiogram, is a non-invasive test that uses sound waves to create images of your heart. It helps doctors monitor your heart's function and structures after initial assessment or treatment.

This service was performed 57 times for 55 patients

Use of a drug to induce depression of consciousness by physician performing a procedure (5 years or older), initial 15 minutes

This procedure involves a doctor administering a medication to reduce your consciousness during a procedure. This helps in managing discomfort and anxiety. The initial application lasts for 15 minutes and is for individuals aged 5 years or older.

This service was performed 54 times for 53 patients

Physician Visit Costs



The typical physician office visit costs for Medicare beneficiaries in this area are: $30.57 for a new patient copayment and $23.43 for an established patient copayment.

The pricing information below displays the copayment minimum, maximum and average amount that patients under Medicare are charged when visiting this provider as a new or established patient. Please keep in mind that these prices are just for reference purposes, and the actual prices charged by the provider might be different.

For patients covered under private health plans the prices below are also useful as healthcare pricing for private insurance is usually established as a function of Medicare prices. Private insurance covered patients should check their individual plans to determine the exact pricing.

The prices below reflect the costs for new and established patients in the 35243 ZIP code area.

New Patients Visit Costs *

The most utilized procedure code for new patients office visits is 99204

  • Average New Patient Price $122.31
  • Minimum New Patient Price $52.65
  • Maximum New Patient Price $161.63
  • Average New Patient Copayment $30.57
  • Minimum New Patient Copayment $13.16
  • Maximum New Patient Copayment $40.4

Established Patients Visit Costs *

The most utilized procedure code for established patients office visits is 99214

  • Average Established Patient Price $93.72
  • Minimum Established Patient Price $16.56
  • Maximum Established Patient Price $131.65
  • Average Established Patient Copayment $23.43
  • Minimum Established Patient Copayment $4.14
  • Maximum Established Patient Copayment $32.91

* The physician office visit costs information is generated by statistical analysis of similar providers in the same geographical area. The pricing information above IS NOT the amount charged by this provider.

Overall MIPS Quality Performance

The provider participated in CMS Quality Payment Program under the Merit-based Incentive Payment System (MIPS) and has an overall final score of 78.57, based on four performance areas: quality, improvement activities, promoting interoperability, and cost. The purpose of this information is to help people with Medicare make informed decisions and incentivize doctors and clinicians to maximize performance.

The Merit-based Incentive Payment System (MIPS) is a way providers could use to participate in CMS Quality Payment Program (QPP). The MIPS program affects clinician reimbursement for Part B covered professional services and also rewards them for improving the quality of patient care and outcomes.

  • Final Score: 78.57 out of 100

    The MIPS program evaluates providers across multiple categories with a specific weight for each category resulting a in a MIPS final score that ranges from 0 to 100 points. The MIPS Final Score determines whether providers receive a negative, neutral or positive MIPS payment adjustment.

  • Quality Score: 81.6

    The Quality category assesses providers performance on clinical practices and patient outcomes under the traditional MIPS program. The quality measures help identify the quality of healthcare processes, outcomes, and patient experiences. The Quality measure category compromises 40% providers final MPIS scores.

    There are six collection types for MIPS quality measures: Electronic Clinical Quality Measures (eCQMs), MIPS Clinical Quality Measures (CQMs), Qualified Clinical Data Registry (QCDR) Measures, Medicare Part B claims measures, CMS Web Interface measures and The Consumer Assessment of Healthcare Providers and Systems (CAHPS) for MIPS Survey.

  • Promoting Interoperability Score: 100

    The Interoperability category measures the providers ability to use technology to exchange and make use of healthcare information in a way that is less burdensome and improves outcomes. The Interoperability measure category compromises 25% providers final MPIS scores.

    The MIPS Interoperability measure focuses on the use of certified electronic health record technology (CEHRT) to improve patient access health information, the exchange of information between clinicians and pharmacies and the systematic collection, analysis, and interpretation of healthcare data.

  • Improvement Activities Score: 40

    The Improvement Activities performance category evaluates the providers participation in clinical activities that support the improvement of clinical practice, care delivery, and outcomes. Providers have the option to choose 2 to 4 activities from an inventory of over 100 improvement activities. Providers typically choose the activities that best fit their needs. The improvement activities measure category compromises 15% providers final MPIS scores.

    The Improvement measures aim to better patient engagement, patient safety and other areas of patient care. The Improvement Activities category compromises 15% of providers final MPIS scores.

  • Cost Score: 46.96

    The Cost performance category asses the amount and types of services provided and how clinicians coordinate care and seek improvement of health outcomes by ensuring patients receive the appropriate services.

    Although providers don't determine the price of healthcare services they are important in delivering high-quality care at a reasonable cost. The Cost measures category compromises 20% of providers final MPIS scores.

  • Cost Score: 46.96

    The Cost performance category asses the amount and types of services provided and how clinicians coordinate care and seek improvement of health outcomes by ensuring patients receive the appropriate services.

    Although providers don't determine the price of healthcare services they are important in delivering high-quality care at a reasonable cost. The Cost measures category compromises 20% of providers final MPIS scores.

Find Provider Hospital Affiliations - Privileges

Doctors and physicians must apply for hospital privileges to treat patients at hospitals. Find out if your doctor has privileges to practice at your preferred hospital by using the hospital affiliation information below based on recent medical claims.

Hospital affiliation is identified through self-reporting data, inpatient, outpatient, physician and ancillary service claims linked by the medical claims NPI number and place of service code. Additionally, to further determine provider hospital affiliation the clinician must have provided services to at least three patients on three different dates in the last 12 months. Byron Colley is affiliated with the following medical facilities:

Hospital Name Address Phone Hospital Type Overall Rating
MEMORIAL HOSPITAL AT GULFPORT4500 13TH STREET
GULFPORT, MS 39502
(228) 867-4000Acute Care Hospitals
SINGING RIVER GULFPORT15200 COMMUNITY ROAD
GULFPORT, MS 39503
(228) 575-7000Acute Care Hospitals
MERIT HEALTH RIVER OAKS1030 RIVER OAKS DRIVE
FLOWOOD, MS 39232
(601) 932-1030Acute Care Hospitals

Reviews for DR. BYRON JUDSON COLLEY III M.D.

There are currently no reviews for this provider. Be the first person to share your experience with this provider by filling out our review form. Your insights are appreciated and will help others make informed decisions.

NPI Validation Check Digit Calculation


The following table explains the step by step NPI number validation process using the ISO standard Luhn algorithm.

Start with the original NPI number, the last digit is the check digit and is not used in the calculation.
1679665640
Step 1: Double the value of the alternate digits, beginning with the rightmost digit.
261491261068
Step 2: Add all the doubled and unaffected individual digits from step 1 plus the constant number 24.
2 + 6 + 1 + 4 + 9 + 1 + 2 + 6 + 1 + 0 + 6 + 8 + 24 = 70
Step 3: because the number obtained in step 2 ends in zero, the check digit is zero.
0

The NPI number 1679665640 is valid because the calculated check digit 0 using the Luhn validation algorithm matches the last digit of the original NPI number.

Other Providers at the Same Location


The following 7 providers are registered at the same or nearby location.

NPI Name / Type Taxonomy Address
1225513401 LOGAN GILMORE
Individual
Nurse Practitioner3686 GRANDVIEW PKWY STE 720
BIRMINGHAM, AL 35243
(205) 971-7500
1023202306DR. GUSTAVO XAVIER MORALES MD
Individual
Internal Medicine (Clinical Cardiac Electrophysiology)3686 GRANDVIEW PKWY STE 720
BIRMINGHAM, AL 35243
(205) 971-7500
1215267299MRS. TANEAKA ANNICE ROWE-HOUSER CRNP
Individual
Nurse Practitioner (Adult Health)3686 GRANDVIEW PKWY STE 720
BIRMINGHAM, AL 35243
(205) 971-7500
1750894382 AMY SALMON JAMES CRNP
Individual
Nurse Practitioner3686 GRANDVIEW PKWY STE 720
BIRMINGHAM, AL 35243
(052) 971-7500
1124621594 ANGELA CHRISTINE METCALF CRNP
Individual
Nurse Practitioner (Family)3686 GRANDVIEW PKWY STE 720
BIRMINGHAM, AL 35243
(205) 971-7500
1568436301DR. DAVID SCHULTZ M.D.
Individual
Internal Medicine (Interventional Cardiology)3686 GRANDVIEW PKWY STE 720
BIRMINGHAM, AL 35243
(052) 971-7563
1679241251 EMILY BEHLING CRNP
Individual
Nurse Practitioner (Family)3686 GRANDVIEW PKWY STE 720
BIRMINGHAM, AL 35243
(812) 447-8322

Frequently Asked Questions

The NPI number assigned to this healthcare provider is 1679665640, enumerated in the NPI registry as an "individual" on September 28, 2006

The provider is located at 3686 Grandview Pkwy Ste 720 Birmingham, Al 35243 and the phone number is (205) 971-7500

The provider's speciality is Internal Medicine with taxonomy code 207RC0001X with a focus in Clinical Cardiac Electrophysiology

The provider has more than 26 years of experience.

The provider might be accepting Accepts: Ambetter from Arkansas Health & Wellness, Ambetter. Please consult your insurance carrier or call the provider to make sure your health plan is currently accepted.

Yes, as of June 20, 2025 the provider is registered in PECOS and is eligible to order health care services or supplies for Medicare patients. If you are a beneficiary the provider is eligible to order or refer: Part B Clinical Laboratory and Imaging, Durable Medical Equipment (DME), a Home Health Agency (HHA) and Power Mobility Devices.

The provider has an overall high rating in the following quality measures: quality clinical practices and patient outcomes and experiences , uses technology to exchange and make use of healthcare information.

Medicare beneficiaries should expect a typical cost of $122.31 with an average copayment of $30.57 for new patient appointments. Established patients should expect a typical charge of $93.72 and an average copayment of 23.43. Please review your insurance plan or contact the provider directly to determine your specific costs.

The most common procedures or services performed by this practitioner are: Blood creatinine level, Comprehensive electrophysiologic evaluation with catheter destruction of abnormality causing atrial fibrillation (uncoordinated contraction of upper chambers of heart) by pulmonary vein isolation, Comprehensive electrophysiologic evaluation with catheter destruction of abnormality of upper chamber of heart causing supraventricular tachycardia (rapid heart rate), Coronary angioplasty and stenting, Ct scan of blood vessels of chest with contrast, Electrocardiogram (ecg) up to 30 days continuous with review and report by health care professional, Established patient office or other outpatient visit, 20-29 minutes, Established patient office or other outpatient visit, 30-39 minutes, Established patient office or other outpatient visit, 40-54 minutes, Evaluation of cardiac rhythm monitor system, remote up to 30 days, Evaluation of single, dual, multiple lead or leadless pacemaker system or implantable defibrillator system, remote up to 90 days, Evaluation of single, dual, multiple lead or leadless pacemaker system, remote up to 90 days, Evaluation of single, dual, or multiple lead implantable defibrillator system, remote up to 90 days, External shock to heart to regulate heart beat, Follow-up hospital inpatient care per day, typically 25 minutes, Follow-up hospital inpatient care per day, typically 35 minutes, Hospital discharge day management, more than 30 minutes, Initial hospital inpatient care per day, typically 70 minutes, Insertion of catheters and destruction of tissue to treat abnormal heart rhythm, Insertion of heart rhythm monitor under skin, Insertion of needle into vein for collection of blood sample, Insertion of pacemaker and upper and lower heart chamber electrode, Interrogation device evaluation(s), (remote) up to 30 days; implantable cardiovascular physiologic monitor system, implantable loop recorder system, or subcutaneous cardiac rhythm monitor system, remote data acquisition(s), receipt of transmissions and tec, Low osmolar contrast material, 300-399 mg/ml iodine concentration, per ml, Management using the results of remote vital sign monitoring per calendar month, first 20 minutes, New patient office or other outpatient visit, 45-59 minutes, New patient office or other outpatient visit, 60-74 minutes, Pacemaker insertion or repair, Programming of dual lead implantable defibrillator system, Programming of dual lead pacemaker system, Programming of heart rhythm stimulation after drug infusion, Programming of multiple lead implantable defibrillator system, Programming of multiple lead pacemaker system, Remote monitoring of physiologic parameters, initial set-up and patient education on use of equipment, Repair of left upper heart chamber with implant with review by radiologist, Routine electrocardiogram (ecg) using at least 12 leads with interpretation and report, Routine electrocardiogram (ecg) using at least 12 leads with interpretation and report only, Ultrasound of heart blood flow, valves and chambers, Ultrasound of heart blood flow, valves and chambers, follow-up, Ultrasound of heart with color-depicted blood flow, rate and valve function, Ultrasound of heart with color-depicted blood flow, rate, direction and valve function, Ultrasound of heart with color-depicted blood flow, rate, direction and valve function, Ultrasound of heart with probe in esophagus, with report, Ultrasound of heart, follow-up and Use of a drug to induce depression of consciousness by physician performing a procedure (5 years or older), initial 15 minutes.

The practitioner is affiliated to the following hospital(s): MEMORIAL HOSPITAL AT GULFPORT, SINGING RIVER GULFPORT and MERIT HEALTH RIVER OAKS. Hospital affiliations are identified through self-reporting data and service claims based on the place of service.

This NPI record was last updated on September 28, 2006. To officially update your NPI information contact the National Plan and Provider Enumeration System (NPPES) at 1-800-465-3203 (NPI Toll-Free) or by email at [email protected].
NPI Profile data is regularly updated with the latest NPI registry information, if you would like to update or remove your NPI Profile in this website please contact us.